Welcome to the company ! we have many years of professional experience !
rsdgj@pyzyrsd.com +86 513525609655

Consequences of direct discharge of acidic wastewater

Established in 2001, Puyang Zhong Yuan Restar Petroleum Equipment Co.,Ltd, “RSD” for short, is Henan’s high-tech enterprise with intellectual property advantages and independent legal person qualification. With registered capital of RMB 50 million, the Company has two subsidiaries-Henan Restar Separation Equipment Technology Co., Ltd We are mainly specialized in R&D, production and service of various intelligent separation and control systems in oil&gas drilling,engineering environmental protection and mining industries.We always take the lead in Chinese market shares of drilling fluid shale shaker for many years. Our products have been exported more than 20 countries and always extensively praised by customers. We are Class I network supplier of Sinopec,CNPC and CNOOC and registered supplier of ONGC, OIL India,KOC. High quality and international standard products make us gain many Large-scale drilling fluids recycling systems for Saudi Aramco and Gazprom projects.

Certificate of Honor

Get in touch with us

We will confidentially process your data and will not pass it on to a third party.

Consequences of direct discharge of acidic wastewater
Ammonia-Nitrogen Removal by Breakpoint Chlorination
Ammonia-Nitrogen Removal by Breakpoint Chlorination

Ammonia in wastewater and water was oxidized by chlorine to chiefly nitrogen gas with a residual NH 3 -N concentration of less than 0.1 mg/i. The chlorine was applied in the gaseous state to a stream of water and base before mixing with the wastewater, or as a solution of hypochlorite.

Achiever Essays - Your favorite homework help service ...
Achiever Essays - Your favorite homework help service ...

Achieveressays.com is the one place where you find help for all types of assignments. We write high quality term papers, sample essays, research papers, dissertations, thesis papers, assignments, book reviews, speeches, book reports, custom web content and business papers.

BOQU - Water Quality Analyzer Water Quality Sensor ...
BOQU - Water Quality Analyzer Water Quality Sensor ...

Through excessive use of resources, China's economy has developed rapidly. But at the same time, a series of environmental problems emerged. The most obvious part is water pollution, such as industrial ,wastewater,, medical ,wastewater,, river pollution, heavy metal pollution, drinking water problem, and domestic sewage.

Lesson 8: Nitrification and Denitrification
Lesson 8: Nitrification and Denitrification

Breakpoint chlorination requires relatively high chlorine dosages per unit of ammonia present in the wastewater. In general, about 10 pounds of chlorine are required to oxidize one pound of ammonia-nitrogen. Because of the high chlorine demand, breakpoint chlorination is not used as the primary ammonia (or nitrogen) removal process.

Cyanide Wastewater Treatment Chlorine Oxidation ...
Cyanide Wastewater Treatment Chlorine Oxidation ...

30/3/2021, · In the presence of free ,chlorine,, ,ammonia, is rapidly converted to ,nitrogen, gas. 3Cl2+6NaOH+(NH4)2CO3+Na2CO3^2NaHCO3+N2|+6NaCl+6H2O. As with all breakpoint chlorination applications, other products such as N2O and NCl3 are also formed. Another way of hydrolyzing the cyanate is to employ ,acid, conditions (pH<2.5). 2NaCNO+H2SO4+4H2O^(NH4)2SO4+2NaHCO3

Chloramines as a disinfectant - Water Treatment and ...
Chloramines as a disinfectant - Water Treatment and ...

The amounts of ,chlorine, and ,ammonia, in the water also influence the origination of ,chloramines,. The ,chlorine,/ ,ammonia, rate is ideally 6:1. During chloramine production the rate is usually 3-5:1. When ,ammonia, concentrations are higher, more di- and trichloramines are formed. Organic ,chloramines, can also be formed during these reactions.

Effect of Ammonia Nitrogen and Dissolved Organic Matter ...
Effect of Ammonia Nitrogen and Dissolved Organic Matter ...

For the first time, ,ammonia nitrogen, (NH 3 N) was found to significantly influence genotoxicity during ,wastewater, chlorination. After chlorination, the genotoxicity decreased in ,wastewater, with a low NH 3 N concentration (<10∼20 mg/L), but it increased notably in ,wastewater, with a …

Ammonia - Wikipedia
Ammonia - Wikipedia

Ammonia, is a compound of ,nitrogen, and hydrogen with the formula NH 3.A stable binary hydride, and the simplest pnictogen hydride, ,ammonia, is a colourless gas with a distinct characteristic of a pungent smell. It is a common nitrogenous waste, particularly among aquatic organisms, and it contributes significantly to the nutritional needs of terrestrial organisms by serving as a precursor to ...

Page 3: Guidelines for Canadian Drinking Water Quality ...
Page 3: Guidelines for Canadian Drinking Water Quality ...

Free ,chlorine,: the amount of ,chlorine, present in water as dissolved gas (Cl 2), hypochlorous ,acid, (HOCl), and/or hypochlorite ion (OCl-) that is not combined with ,ammonia, or other compounds in water. Combined ,chlorine,: the sum of the species resulting from the reaction of free ,chlorine, with ,ammonia, (NH 3 ), including monochloramine (NH 2 Cl), dichloramine (NHCl 2 ), and trichloramine (,nitrogen, ...

Advanced Disinfection Study Guide
Advanced Disinfection Study Guide

Adding ,chlorine, to treated ,wastewater,, which has ,ammonia, (NH3), will cause a reaction, where hypochlorous ,acid, (HOCl) reacts with ,ammonia, to form chloramines. Chloramines are not effective disinfecting compounds. The reactions and type of chloramines formed are: NH3 + HOCl --> NH2Cl + H2O = Monochloramine NH2Cl + HOCl --> NHCl2 + H2O =Dichloramine

Total Ammonia in Water and Wastewater - CHEMSCAN
Total Ammonia in Water and Wastewater - CHEMSCAN

Ammonia can be found in surface water, groundwater and wastewater. When this water is disinfected through the addition of chlorine, there are interactions between the chlorine and ammonia that result in the formation of chloramines. The exact form of chloramine is a function of the chlorine to nitrogen ratio, pH and reaction time.

Disinfection of Water & WW - Norweco - Norwalk Wastewater ...
Disinfection of Water & WW - Norweco - Norwalk Wastewater ...

treatment processes do little or nothing to stabilize nitrogen compounds. If the wastewater is retained in a collection system, or in a septic tank for several hours, a high percentage of the organic nitrogen undergoes the “ammonification” process whereby it is converted to ammonia-nitrogen. Chlorine readily combines with ammonia 2 3)

Total Nitrogen in Wastewater - CHEMSCAN
Total Nitrogen in Wastewater - CHEMSCAN

The Total ,Nitrogen, load on the process is the sum of the soluble organic ,nitrogen, and ,ammonia, contributed by the incoming ,wastewater, plus any ,nitrogen, contributed by the Return Activated Sludge plus the ,nitrogen, from any recirculation flow back from the nitrification stages of the ,treatment, process.

Biological and Chemical Wastewater Treatment Processes ...
Biological and Chemical Wastewater Treatment Processes ...

2/12/2014, · Chemical ,treatment, is now considered as a tertiary ,treatment, that can be more broadly defined as “,treatment, of ,wastewater, by a process involving chemical ,treatment,”. The mostly implemented chemical ,treatment, processes are: chemical precipitation, neutralization, adsorption, disinfection (,chlorine,, ozone, ultraviolet light), and ion exchange.

Advanced wastewater treatment - SlideShare
Advanced wastewater treatment - SlideShare

When chlorine is added to wastewater containing ammonia-nitrogen, it initially reacts with hypochlorous acid to form chloramines. Continued addition of chlorine after "breakpoint" (occurring when free chlorine residual is formed) converts chloramines to nitrogen gas.

Understanding Laboratory Wastewater Tests: I. ORGANICS ...
Understanding Laboratory Wastewater Tests: I. ORGANICS ...

14/10/2010, · To ensure proper biological activity during the BOD test, a ,wastewater, sample: Must be free of ,chlorine,. If ,chlorine, is present in the sample, a dechlorination chemical (e.g, sodium sulfite) must be added prior to testing. Needs to be in the pH range of 6.5-7.5 S.U. If the sample is outside this range, then ,acid, or base must be added as needed.

Chat Online Inquiry Email

Business cooperation

+86 513525609655

Company address

Road West, North Branch, Jingkai Road, Puyang City