gas testing waste water up-to-standard emission treatment methods involves

Established in 2001, Puyang Zhong Yuan Restar Petroleum Equipment Co.,Ltd, “RSD” for short, is Henan’s high-tech enterprise with intellectual property advantages and independent legal person qualification. With registered capital of RMB 50 million, the Company has two subsidiaries-Henan Restar Separation Equipment Technology Co., Ltd We are mainly specialized in R&D, production and service of various intelligent separation and control systems in oil&gas drilling,engineering environmental protection and mining industries.We always take the lead in Chinese market shares of drilling fluid shale shaker for many years. Our products have been exported more than 20 countries and always extensively praised by customers. We are Class I network supplier of Sinopec,CNPC and CNOOC and registered supplier of ONGC, OIL India,KOC. High quality and international standard products make us gain many Large-scale drilling fluids recycling systems for Saudi Aramco and Gazprom projects.

Certificate of Honor

Get in touch with us

We will confidentially process your data and will not pass it on to a third party.

gas testing waste water up-to-standard emission treatment methods involves
Treating Plating Wastewater | Products Finishing
Treating Plating Wastewater | Products Finishing

1/3/2001, · The plating process typically involves, alkaline cleaning, acid pickling, plating, and, rinsing., Copious amounts of wastewater are generated through these steps, especially during, rinsing., Additionally, batch dumping spent acid and cleaning solutions contributes to …

METHOD FOR TREATING ELECTROLESS COPPER PLATING WASTEWATER ...
METHOD FOR TREATING ELECTROLESS COPPER PLATING WASTEWATER ...

A method for combined treatment of electroless ,copper plating wastewater, includes oxidizing hydroxyl-containing organic amine complexants with hydrogen peroxide or sodium hypochlorite to organic ,acid, complexants containing amine group (or amino group) and carboxyl group, precipitating the carboxyl-containing complexants using synergistic effect of ferrous ions and calcium ions and ...

Surface Treatment Chemical Products
Surface Treatment Chemical Products

Sulfuric ,acid, type bright pickling process for ,copper, and ,copper, alloy. Easy ,wastewater, treatment. Generates no harmful gas. CHP-200 X Sulfuric ,acid, (98%) Hydrogen peroxide(35%) 20L 100-200mL 100-200mL 15-150mL Application & Features Usage Products Conc. (/L) Temp. (℃) Pack-ing 20-50 7. WATER-SOLUBLE RUST PREVENTION AGENT Process EBAFIN G-800

Copper Removal from Electroplating Wastewater by ...
Copper Removal from Electroplating Wastewater by ...

In particular,, electroplating wastewater contains a wide range of copper compounds,, in addition to Fe 3+, Zn 2+, Cd 2+, Ni 2+, Cr 3+, and many other heavy metal ions. Not only do these represent a waste of resources, but as environmental pollutants they are hazardous to human and animal health [ 7 – 9

University of Technology Iraq
University of Technology Iraq

B.E. 2101 Engineering Mechanics: Theory: 3hrs./ Week Tutorial: 1hr./ Week: Statics: 1- Introduction to scalar and vector quantities, forces, moments, couples. 16. 2 ...

Copper plating from hydrochloric acid
Copper plating from hydrochloric acid

Copper plating from hydrochloric acid, 2005. Hello, Could anyone recommend a source for paper / publication on ,plating, metals in Hydrochloric ,acid,? There seems to be precious little available on this topic. As you can see from the above I am a ,plating, noob. Edouard Gerard waste ,acid, recycling - …

Removal of heavy metals in plating wastewater using ...
Removal of heavy metals in plating wastewater using ...

In order to remove chelating or organic materials in plating wastewater, oxidation using sodium hypochlorite was performed as a pretreatment. When carboxylated alginic acid bead was applied in a packed-bed contactor, the breakthrough point of copper ion in the acid-alkaline wastewater appeared around 350 bed volumes; the breakthrough point of nickel ion in the chelating wastewater emerged …

Treatment of complexed copper in waste water
Treatment of complexed copper in waste water

27/2/2019, · A. Copper responds very well to ferrous sulfide. It is generated in situ by adding a little ferrous sulfate (about 1 - 2 pounds per 1000 gallons of wastewater) at pH 4 or thereabouts, raising the pH to 9 with sodium hydroxide, and dosing the waste with sodium sulfide. This should be used sparingly - about a pound per 1000 gallons of wastewater.

A REVIEW OF ACID COPPER PLATING BATH LIFE EXTENSION …
A REVIEW OF ACID COPPER PLATING BATH LIFE EXTENSION …

Bless*, D R. A REVIEW OF ACID ,COPPER PLATING, BATH LIFE EXTENSION AND ,COPPER, RECOVERY FROM ACID ,COPPER, BATHS. ,PLATING, AND SURFACE FINISHING JOURNAL 88(10 ... and improve sorption-based separation technologies to reduce the discharge of chemicals and minimize the need for ,wastewater, treatment. In 1995, EPA established a Common Sense ...

(PDF) The Mississippi University Research Consortium for ...
(PDF) The Mississippi University Research Consortium for ...

The Mississippi University Research Consortium for the Utilization of Biomass: Production of Alternative Fuels from Waste Biomass Initiative

METHOD FOR TREATING ELECTROLESS COPPER PLATING …
METHOD FOR TREATING ELECTROLESS COPPER PLATING …

A method for combined treatment of electroless ,copper plating wastewater, includes oxidizing hydroxyl-containing organic amine complexants with hydrogen peroxide or sodium hypochlorite to organic acid complexants containing amine group (or amino group) and carboxyl group, precipitating the carboxyl-containing complexants using synergistic effect of ferrous ions and calcium ions and ...

Recovery/Recycling Methods for Metal Finishers | Products ...
Recovery/Recycling Methods for Metal Finishers | Products ...

The recovered acid goes back to the process bath, while rejected metals can go to waste treatment or another recovery technology. Electrowinning can remove copper, cadmium, zinc, brass, tin-lead, gold, silver and nickel from plating wastes.

Steel Substrate acid copper plating solution Bright Copper ...
Steel Substrate acid copper plating solution Bright Copper ...

It is suitable for cyanide free copper plating on steel substrate (direct electroplating of acid copper, no need of pre nickel plating or cyanide alkali copper, no need of electrifying and entering the bath at the same time). 2. It does not contain cyanide, so it is easy to treat the wastewater and has little pollution to the environment. 3.

Treatment of electroplating wastewater using the freezing ...
Treatment of electroplating wastewater using the freezing ...

1/3/2020, · However, the, washing wastewater, from the frequently used, acid copper,, pyrophosphate, copper,, and chromium electroplating are strongly acidic, having a pH less than 2, while that from alkali, copper, process and zincate zinc, plating, are strongly alkaline, with pH greater than 12.

A REVIEW OF ACID COPPER PLATING BATH LIFE EXTENSION …
A REVIEW OF ACID COPPER PLATING BATH LIFE EXTENSION …

Bless*, D R. A REVIEW OF ,ACID COPPER PLATING, BATH LIFE EXTENSION AND ,COPPER, RECOVERY FROM ,ACID COPPER, BATHS. ,PLATING, AND SURFACE FINISHING JOURNAL 88(10 ... and improve sorption-based separation technologies to reduce the discharge of chemicals and minimize the need for ,wastewater, treatment. In 1995, EPA established a Common Sense ...

Copper Removal from Electroplating Wastewater by ...
Copper Removal from Electroplating Wastewater by ...

In particular, electroplating wastewater contains a wide range of copper compounds, in addition to Fe 3+, Zn 2+, Cd 2+, Ni 2+, Cr 3+, and many other heavy metal ions. Not only do these represent a waste of resources, but as environmental pollutants they are hazardous to human and animal health [ 7 – 9